YEERS is a Hull-based, MCS-certified heat pump installer covering the whole Humber region — East Yorkshire, North Yorkshire and northern Lincolnshire. This page is the regional overview: which councils and towns we cover, why the Humber is unusually well-suited to air source heat pumps, what the grant position is in 2026, and what an install actually involves from survey to commissioning.
Our page on air source heat pumps for Yorkshire homes covers what a survey involves and what the quote includes.
Towns and councils we cover
Our engineering base is Hull, with survey and install teams working both banks of the Humber. Every town below is inside the standard service radius — no travel surcharge, no third-party subcontracting.
| Town | Local authority | Typical housing stock we survey |
|---|---|---|
| Hull | Hull City Council | Pre-1940 terraces, 1960s–80s semis, city-centre conversions |
| Beverley | East Riding of Yorkshire Council | Georgian/Victorian town houses, conservation-area properties, modern estates |
| Driffield | East Riding of Yorkshire Council | Wolds farmhouses, barn conversions, off-gas-grid villages |
| Bridlington | East Riding of Yorkshire Council | Coastal bungalows, seafront flats, 1930s semis |
| Hornsea | East Riding of Yorkshire Council | Detached bungalows, retirement stock, holiday lets |
| Goole | East Riding of Yorkshire Council | Terraced housing, canalside newer builds, surrounding oil-heated villages |
| Grimsby | North East Lincolnshire Council | Dense terraces, ex-council semis, Wolds-edge rural detached |
| Cleethorpes | North East Lincolnshire Council | Seafront Victorian, bungalows, converted flats |
| Immingham | North East Lincolnshire Council | Post-war semis, industrial-worker estates, rural smallholdings |
| Scunthorpe | North Lincolnshire Council | 1950s–70s estate housing, larger detached in Isle of Axholme villages |
| Selby | North Yorkshire Council | Market-town terraces, modern estates, off-grid Vale of York farmhouses |
Town-level detail — pricing patterns, common radiator constraints and local planning notes — sits on the dedicated pages for air source heat pumps Grimsby, heat pumps Selby, heat pumps Cleethorpes and heat pumps Immingham.
Why the Humber region suits heat pumps
Two regional characteristics matter more than anything else here.
A large off-gas-grid rural share. The villages ringing Driffield, Grimsby, Selby and the Isle of Axholme are heated substantially by oil and LPG. There is no mains gas connection to compete with, so the alternative to a heat pump is a replacement oil boiler plus a tank plus rising delivered-fuel prices. That is where the running-cost case is strongest and where our conversion rate from survey to install is highest.
A mild, maritime coastal climate. Air source heat pump efficiency falls as outdoor temperature drops. The Humber's coastal strip — Bridlington, Hornsea, Cleethorpes, Immingham — sees fewer deep-cold hours than inland northern England, so seasonal performance holds up well across a typical heating season. Coastal siting does demand marine-grade corrosion protection on the outdoor unit, which we specify as standard within roughly five miles of the shoreline.
Running costs compared
| Heating type | Typical efficiency | Fuel basis | Relative annual cost |
|---|---|---|---|
| Mains gas boiler | ~88% (condensing, real-world) | Mains gas standard tariff | Baseline |
| Oil (kerosene) boiler | ~88% | Delivered, price volatile by tanker load | Above baseline; spikes with oil market |
| LPG boiler | ~88% | Bulk tank or bottled, usually contracted supply | Highest of the four |
| Air source heat pump | SCOP 3.0–4.0 (3–4 kWh heat per 1 kWh electricity) | Electricity; best on a heat-pump tariff | Comparable to gas; clearly cheapest vs oil and LPG |
The honest position: against mains gas, a heat pump is roughly cost-neutral and depends heavily on your tariff and on getting flow temperatures down to 45°C or lower. Against oil and LPG, the saving is real and repeatable — which is why our off-grid installs across the Wolds and the Vale of York are the ones customers report back on most positively.
If you already have solar PV, or are adding it alongside the heat pump, export payments come through the Smart Export Guarantee. SEG rates across suppliers span roughly 1p to 27p per kWh: Octopus Outgoing Fixed pays a flat 12p/kWh (the rate since 1 March 2026), while time-of-use tariffs such as Intelligent Flux and Agile Outgoing can reach around 27p at peak periods. Note that battery storage is not eligible for the Boiler Upgrade Scheme, so any battery sits outside the grant.
The £7,500 grant and how we claim it
The £7,500 Boiler Upgrade Scheme pays £7,500 towards an air source heat pump for eligible homes in England and Wales. Two things to understand:
- You cannot apply yourself. The grant is claimed by the MCS-certified installer and applied to your quote. YEERS handles the Ofgem application, the voucher and the redemption — you see the deduction, not the paperwork.
- Batteries are not eligible. If you are pairing a heat pump with battery storage, the BUS covers the heat pump only.
Separately, VAT on domestic heat pump installation is 0% until 31 March 2027, reverting to 5% after that date (HMRC VAT Notice 708/6). BUS plus the VAT relief is the live combination for 2026 installs.
What MCS certification actually guarantees
MCS certification is not a badge — it is the gate. Without an MCS-certified installer there is no BUS grant, and the design standards it enforces are the ones that decide whether your system is cheap or expensive to run:
- A room-by-room heat loss calculation to MCS 3005, not a rule-of-thumb sizing off floor area
- Emitter sizing checked against the design flow temperature, so radiators are replaced where the maths requires it
- A performance estimate issued before you commit, and a handover pack on completion
- Access to consumer-code redress if something goes wrong
YEERS installs carry a 10-year workmanship warranty alongside the manufacturer's product warranty.
Install process and timescales
| Stage | What happens | Typical timing |
|---|---|---|
| 1. Enquiry and desktop review | Property, current fuel, EPC check | Within 2 working days |
| 2. Home survey | Heat loss survey, emitter and cylinder assessment, siting | Week 1–2 |
| 3. Design and quote | MCS design, BUS grant applied to the price | Week 2–3 |
| 4. DNO notification | Northern Powergrid connection notification submitted | Runs alongside scheduling |
| 5. Installation | Unit, cylinder, pipework, controls, any radiator changes | 2–4 days on site |
| 6. Commissioning and handover | Balancing, weather compensation set up, MCS certificate issued | Final day |
Northern Powergrid notification
The distribution network operator for the entire area — Hull, East Riding, North East Lincolnshire, North Lincolnshire and the Selby district — is Northern Powergrid (Yorkshire). Every heat pump install must be notified to them. Most domestic units qualify for connect-and-notify, meaning we install first and submit the notification within the required window. Larger units, three-phase properties or constrained rural feeders may require prior approval before we can book the install date; we identify this at survey stage rather than on the day, so it never becomes a surprise delay.
Next step
Send us your postcode, current heating fuel and rough property size through the quote form. We will tell you whether your property is a straightforward BUS-grant install, what the likely emitter work is, and what the net price looks like after the £7,500 deduction — before anyone visits.
Frequently asked questions
Who are the best ASHP installers in East Yorkshire and Humberside?
Look for three things rather than a ranking: MCS certification (without it there is no £7,500 Boiler Upgrade Scheme grant), a genuine room-by-room heat loss survey to MCS 3005 rather than a floor-area estimate, and a local engineering base so warranty callouts do not involve a two-hour drive. YEERS is Hull-based and MCS-certified, covering Hull, East Yorkshire, North Yorkshire and Lincolnshire with a 10-year workmanship warranty.
Do I qualify for the £7,500 Boiler Upgrade Scheme (£9,000 off-gas) in the Humber region?
The grant covers eligible homes across England and Wales, so every town in our coverage area is in scope. You generally need to be replacing a fossil fuel system (gas, oil, LPG or electric) in a property with a valid EPC and no outstanding loft or cavity wall insulation recommendations. You cannot apply yourself — your MCS-certified installer claims it and deducts it from your quote. Batteries are not eligible under the scheme.
Are heat pumps worth it if my village near Grimsby or Driffield is off the gas grid?
This is the strongest case in the region. Off-grid properties currently run on oil or LPG, both of which are more expensive per unit of delivered heat than a heat pump running at a seasonal efficiency of 3.0–4.0. There is no cheap mains gas alternative to compare against, and you also lose the tank, the deliveries and the annual oil boiler service. Many of the villages around Grimsby, Driffield and Selby fall into this category.
Which council do I deal with for planning in my area?
Hull is Hull City Council; Beverley, Bridlington, Driffield, Hornsea and Goole are East Riding of Yorkshire Council; Grimsby, Cleethorpes and Immingham are North East Lincolnshire Council; Scunthorpe is North Lincolnshire Council; and Selby is North Yorkshire Council. Most domestic air source heat pumps are permitted development, but listed buildings and conservation areas — common in central Beverley and parts of Bridlington — need checking before siting is fixed.
Do I need permission from Northern Powergrid before installing a heat pump?
Northern Powergrid (Yorkshire) is the DNO for the whole of East Yorkshire, Hull, northern Lincolnshire and the Selby district, and every install must be notified to them. Most single-phase domestic units are handled under connect-and-notify, meaning the notification is submitted after installation within the required window. Larger units, three-phase supplies or constrained rural feeders can require approval beforehand — we identify that at survey, not on install day.
How long does an air source heat pump installation take from first enquiry?
Typically four to eight weeks end to end. The survey usually happens within one to two weeks of enquiry, the MCS design and grant-applied quote follows within another week, and the on-site work itself takes two to four days depending on whether the cylinder location changes and how many radiators need upsizing. Northern Powergrid notification runs in parallel with scheduling rather than adding to the timeline.
Last updated August 2026 · YEERS — MCS-certified installers, Hull & Yorkshire.